To ensure your battery's longevity,you should: recharge it'at night keep the area where cables are connected to the positive and negative poles clean make sure you are changing the battery fluid regularly have it checked by a mechanic weekly
What is true of a second application of hard wax while the first is setting? Select the correct response: The first application must be with soft wax. The second waxing must be performed on an immediately adjacent area. It cannot be performed on an immediately adjacent area. The second application will make the service more thorough but less expedient.
Why is the travel and work angle important? Because of the jetting force of the electrode end. Because it affects the amount of spatter produced. Because of the force on the welding electrode holder the welding cable has as you move along the weld. They are not important and have little effect on how welds are made.
Electrodes with __ produce welds with the heaviest slag covering the molten weld pool and finished weld bead. cellulose-based fluxes rutile-based fluxes mineral-based fluxes silicon-based fluxes
The purpose behind permitting the grounding electrode connection to be made at the equipment grounding conductor terminal bar of the service rather than to the neutral is to provide a convenient connection point sometimes outside the service disconnecting means enclosure. True False
If 240-volt delta connected systems are not grounded, the voltage to ground is considered 240 volts. the installation is not in compliance with the NEC. the system is required to be grounded. a grounding electrode for the equipment is not required.
The typical voltages for a 120/240 volt, 3-phase, 4-wire delta-connected system are 120 volts phase A to phase B. ) 208 volts phase B to ground. 208 volts phase B to phase C. 240 volts phase C to ground.
At what point should the "No Tractor Flag"be utilized when inputting/verifying the vehicle data? When you are only working on the trailer not the tractor When it is a dropped trailer Never use the No Tractor Flag Use the No Tractor Flag for every work order
What is the primary purpose of a wire map tester? To measure the length of a cable To identify the type of cable used To detect improper termination issues To increase the signal strength in a cable
A transmission fluid leak can be caused by an overfilled transmission. Select one: A. True B. False
9 Multiple Choice 1 point Which of the following is not a measurement function of a DMM? Pressure Voltage Continuity Resistance
An oilless lubricating system uses a well or reservoir in the end bell. A True B False Question 8 Which of the following statements about replacement capacitors is false? A They should have the same capacitance value as the original. B They should have a capacitance value up to $25\% $ greater than the original. C They should never be undersized. D They may have a capacitance value up to $10\% $ greater than the original.
Split-phase motors use a(n) __ to disconnect the start windings as the motor approaches running speed. A unloader B VFD C squirrel cage rotor D centrifugal switch Question 12 On a capacitor-start,induction-run motor, a centrifugal switch or relay disconnects __ when the motor reaches about $75\% $ of its rated speed. A the start winding only B the start capacitor only C both the start winding and start capacitor D both the start capacitor and run capacitor
Just before lifting off a rotary wing pilot must check the weather at the scene for a medical transport. In addition the pilot must also: Know the condition of the patient. Check the weather at the receiving hospital. Inventory all equipment on board the aircraft. Know the experience of the crew setting up the landing zone.
Advantages of ECMs include the following, except __ A ability to maintain constant airflow B easily replaceable brushes C efficient performance D variable speed Question 22 Important motor information such as rated voltage time rating, insulation class frequency, phase, and horsepower can be found on the __ A motor frame B motor nameplate C bearings D shaft
Which type of discontinuity is NEVER visible during visual inspection? underbead cracking porosity toe cracks undercut
The NEC in Table 210.24 shows that the minimum conductor size for branch-circuit wiring is __ 16 AWG 20 AWG 18 AWG 14 AWG
424170 What is the minimum number of trenches that should be dug across a truck-bed, railcar, or barge to acquire a representative sample? 3 (three) 4 (four) 5 (five) 7 (seven)
Nickel alloys should not be heat-treated. Select one: True False
The operator interface audible alarm sounds when there is a hydrogen event. Select true or false. True False