To ensure your battery's longevity,you should: recharge it'at night keep the area where cables are connected to the positive and negative poles clean make sure you are changing the battery fluid regularly have it checked by a mechanic weekly
What is true of a second application of hard wax while the first is setting? Select the correct response: The first application must be with soft wax. The second waxing must be performed on an immediately adjacent area. It cannot be performed on an immediately adjacent area. The second application will make the service more thorough but less expedient.
Why is the travel and work angle important? Because of the jetting force of the electrode end. Because it affects the amount of spatter produced. Because of the force on the welding electrode holder the welding cable has as you move along the weld. They are not important and have little effect on how welds are made.
Electrodes with __ produce welds with the heaviest slag covering the molten weld pool and finished weld bead. cellulose-based fluxes rutile-based fluxes mineral-based fluxes silicon-based fluxes
When you add radiator fluid to the reservoir,how full should it be? Select the correct answer and click Submit. ) Up to the "Full"mark Up to the very top of the reservoir Up to the "Add"mark
Where is the transmission dipstick normally located on a rear-wheel drive vehicle? Select the correct answer and click Submit. At the rear of the engine near the firewall Directly above the steering column and in the middle of the engine At the front of the engine
Which of the following is a key activity in performing tire service and wheel balance? a. Cleaning the battery terminals b. Checking and adjusting tire pressure c. Inspecting the exhaust system d. Changing engine oil
The purpose behind permitting the grounding electrode connection to be made at the equipment grounding conductor terminal bar of the service rather than to the neutral is to provide a convenient connection point sometimes outside the service disconnecting means enclosure. True False
If 240-volt delta connected systems are not grounded, the voltage to ground is considered 240 volts. the installation is not in compliance with the NEC. the system is required to be grounded. a grounding electrode for the equipment is not required.
The typical voltages for a 120/240 volt, 3-phase, 4-wire delta-connected system are 120 volts phase A to phase B. ) 208 volts phase B to ground. 208 volts phase B to phase C. 240 volts phase C to ground.
12. A transformer can be checked for shorted turns using a __ a) VOM set to measure resistance b) VOM set to measure current c) TTR tester d) megger
A GFCI opens a circuit when it detects an improperly grounded receptacle different currents in the conductors of a circuit insulation failure in a conductor large amounts of current in a conductor
When the saw blade starts to bind you should Stop the saw and restart the cut Hold the saw tighter and finish the cut Lift the saw out of the cut Push harder
A __ is the hub of a structured wiring system and is usually located in the basement or garage. It is sometimes called a "distribution center." sub-panel field enclosure service center hub center
Because a kick -back could occur, do not stand directly in front of or behind the machine while it is being used. True False
Question 8 (1 point) Knot efficiency tends to be greater for ropes made of __ a Nylon b Polyester Manila d All of the above
Which stage in the laser printer imaging process involves the application of a uniform negative charge to the imaging drum? Transferring Stage Exposing Stage Charging Stage Developing Stage I want to review this question later. (Optional) Check my answer (Optional)
For a None pump handle detection configuration, which timer would end a transaction? No Fuel Timer End Fuel Timer Pump Finish Timer No Hose Timer
What needs to be done at the FMU if the display reads "Turn Pump Handle On?" Change the divide ratio Power reset the FMU Change pump handle detection to End Only Perform a counts test
When power is lost due to an unforeseen circumstance, a(n) __ detects the outage and automatically switches the power sources from normal to battery backup. Inverter Breaker Uninterruptible power supply Automatic Transfer Switch